Agilent 34401A Service Guide.pdf
IEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. The 34401A may be used to make measurements with the HI and LO inputs connected to mains in such devices, or to the branch outlet itself (up to 300 VAC). However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the protection limits of the 34401A. Note: Voltages above 300 VAC may be measured only in circuits that are isolated from mains. However, transient overvoltages are also present on circuits that are isolated from mains. The Agilent 34401A are designed to safely withstand occasional transient overvoltages up to 2500 Vpk. Do not use this equipment to measure circuits where transient overvoltages could exceed this level. Additional Notices Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see below) indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your local Agilent office, or see www.agilent.com/environment/product for more information. Agilent 34138A Test Lead Set The Agilent 34401A is compatible with the Agilent 34138A Test Lead Set described below. Test Lead Ratings Test Leads - 1000V, 15A Fine Tip Probe Attachments - 300V, 3A Mini Grabber Attachment - 300V, 3A SMT Grabber Attachments - 300V, 3A Operation The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the probe end of the Test Leads. Maintenance If any portion of the Test Lead Set is worn or damaged, do not use. Replace with a new Agilent 3413
资源简介:Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a br...
上传时间: 2022-02-20
上传用户:zinuoyu
资源简介:CCIE Security Exam Certification Guide.pdf,这本书我找了好久才搜到的,看了绝对有帮助。
上传时间: 2015-07-13
上传用户:gundan
资源简介:mc75 mc55 internet service guide
上传时间: 2016-01-03
上传用户:aa17807091
资源简介:verilog golden reference guide.pdf
上传时间: 2014-01-25
上传用户:ma1301115706
资源简介:Vhdl Golden Reference Guide.pdf
上传时间: 2016-02-13
上传用户:362279997
资源简介:real time and embeded guide.pdf 对理解实时操作系统和linux内核之间的交互操作有很好帮助
上传时间: 2013-12-18
上传用户:c12228
资源简介:TI ndk-1_94_0_0 用户使用手册和参考手册Network Developer s Kit (NDK) Software User s Guide.pdf and Network Developer s Kit (NDK) Software Programmer s Reference Guide.pdf
上传时间: 2013-12-27
上传用户:宋桃子
资源简介:GPIB 控制Agilent 34401A
上传时间: 2014-01-04
上传用户:gououo
资源简介:Gesture Design Guide.pdf 详细介绍了ELAN电容式触摸屏的手势设计。 (可用于IPHONE手机输入)
上传时间: 2013-12-24
上传用户:hzy5825468
资源简介:本文档是OpenReports网站上的or-3.0-admin-guide.pdf文档的翻译,它主要介绍了Web报表制作工具OpenReports3.0的功能,是个好东西哦!
上传时间: 2014-06-12
上传用户:bruce5996