# @(#)TL.TXT 3.48.1.8 10/20/94 19:35:04
# file: tl.txt
# date: 3/29/93
# what: TOP LEVEL CONTROL programs error messages
# Edited: joey marquez
#
# 0xxx : info messages
#
0000:
0001:XEMAKE: Missing or modified design files.
0002:XEMAKE: %s
0003:XEMAKE: Rebuilding '%s'.
0004:Errors found by %s! Please examine the '%s.%s' file
for details. Retry after fixing errors.
0005:Errors found! Please examine the '%s.%s' file
for details. Retry after fixing errors.
0006:Deleting database '%s' because of mapping errors
0007:Design successfully mapped. Examine the following report files:
'%s.%s' - Summary of resources used
'%s.%s' - Device pinout
'%s.%s' - Implemented design described in equations
0008:Circuit database '%s' has been created
0009:Written component file to '%s'
0010:Importing successful
0011:Backing up reports and log
0012:Reading netlist '%s.%s'
0013:Writing log to '%s.%s'
0014:Reading design '%s.%s'
0015:Assembling '%s.%s'
0016:Saving the pinlist to '%s.%s'
0017:Importing '%s' to produce '%s.%s'
0018:Writing intelhex programming file to '%s.%s'
0019:Writing jedec programming file to '%s.%s'
0020:Processing PALS to produce new PLD file '%s.%s'
0021:Deleting any simulation models '%s%s%s.%s'
0022:Creating XNF simulation file for circuit '%s'
0023:Converting '%s' from '.%s' file to '.%s' file
0024:XEMAKE: Finished executing the necessary commands to perform integration.
If all commands finished properly, all design files are now up-to-date.
0025:The %s file was successfully created.
0026:Design successfully mapped. Examine the following report files:
'%s.%s' - Summary of resources used
'%s.%s' - Warnings
'%s.%s' - Device pinout
'%s.%s' - Implemented design described in equations
0027:%s Version %s %s
Dated: %s
%s
%s
#
# 1xxx : warning messages
#
1000:
1001:CAUTION: Less than %d bytes remain on disk.
Program requires at least %d bytes to run successfully.
Type 'Ctrl-C' to abort integration.
1002:The file '%s' specifies a non-XC7000 device '%s'.
This is ignored and the '%s' device will be used instead.
1003:XEMAKE: The netlist '%s/%s' for functional simulation
was not created. Check that your design file is correct.
#
# 2xxx : fatal error messages
#
2000:
2001: Pin freezing is ON but a pinlist '%s' has not been saved.
Check your design name and directory or create pinlist using PINSAVE.
2002: The chip table '%s' is missing or can not be read. Verify
that XEPLD was installed properly and that files have read access.
2003:
2004: No XACT variable setting. Please set XACT according to the
XEPLD installation instructions.
2005: Missing or invalid device name '%s'. Use either one of:
XC73144-ssBG225, XC73184-ssPG184,
XC73144-ssPQ160 (ss = 7, 10, 12 or 15)
XC73108-ssBG225, XC73108-ssPQ160,
XC73108-ssPG144, XC73108-ssPC84 (ss = 7, 10, 12, 15 or 20)
XC7372-ssPQ100, XC7372-ssPC84,
XC7372-ssPC68 (ss = 7, 10, 12, or 15)
XC7354-ssPC68, XC7354-ssPC44, (ss = 7, 10, 12, or 15)
XC7336-ssPC44, XC7336-ssPQ44 (ss = 5, 7, 10, 12 or 15)
XC7318-ssPC44, XC7318-ssPQ44, (ss = 5 or 7)
XC7236A-ssPC44 (ss = 16, 20 or 25)
XC7272A-ssPC84, XC7272A-ssPG84,
XC7272A-ssPC68 (ss = 16, 20 or 25)
2006: Invalid JEDEC PAL type option '%s'.
Use '-t PL20V8' or '-t PL22V10'.
2007:
2008:
2009: Bad parameter option '%s'. Supply the correct option and retry.
2010: Required option '%s' missing.
2011:
2012:
2013: The netlist '%s' is missing or can not be read. Check that
you have run WIR2XNF/SDT2XNF (or similar program) and XNFMERGE. Verify
also that you have read access. Otherwise, use another netlist.
2014: Memory allocation failed. Attempt to free up at least
%d bytes of memory.
2015: Can not use JEDEC format for XC7272 designs. Use MAKEPRG instead
to create Intelhex format or integrate design with another XC7000 device.
2016:
2017: Missing design name. Please supply the proper design name
and retry.
2018: No JEDEC filename specified! Specify a JEDEC filename.
2019:
2020: JEDEC file '%s' does not exist or does not have read access.
Verify that this file exists and has read access, or supply
a new jedec file name.
2021: No PAL type specified! Use 'PL20V8' or 'PL22V10'.
2022: The Xilinx EPLD system must make a directory '%s%s%s' to
store the component database. But, a file of the same name already
exists. Please rename this file and try again.
2023: XEMAKE: The xnf translator programs were specified with the option to
place their output in directory '%s%s%s'. But, a file of
the same name already exists. Please rename this file and try again.
2024: Can not read design database '%s'. Make sure you have
run XEMAKE, FITEQN or FITNET. Also, verify that this file has
read access. Otherwise, use another design database.
2025:
2026: File write error on '%s'. Check if there is enough disk space,
if there is write access to files and subdirectories,
or if there is some other hardware failure.
2027: File read error on '%s'. Check if there is enough disk space,
if there is read access to files and subdirectories,
or if there is some other hardware failure.
2028: Component was not created.
2029: The schematic '%s' is missing or can not be read.
Verify that the file exists and has read access.
2030: The behavioral file '%s' can not be read.
Verify that the file exists and has read access. Then, retry.
2031: The options supplied are incomplete or can not be used together.
Supply the proper option(s) according to the following usage:
2032: The netlist '%s' can not be read.
Verify that the file exists and has read access.
2033: The makefile '%s' can not be created by XEMAKE.
Verify that there is sufficient disk space and that your files
have write access.
2034: The makefile '%s' is missing or can not be read by XEMAKE.
Verify that the makefile exists and has read access, supply a new
makefile, or create another makefile by running XEMAKE with
the -g option.
2035: The file '%s', which is needed to build '%s', is missing
or can not be read by XEMAKE. Verify that this file exists and has
read access.
2036: Orcad designs (*.sch) are meant for integration
on DOS only. Specify another schematic or run XEPLD on a PC.
2037: The behavioral file '%s' is missing or can not be read.
Verify that this file exists and has read access. If this was originally
a JEDEC file, run JED2PLD. If originally an XABEL file, run ABL2PLD.
Otherwise, use another behavioral file and retry.
2038: The target file '%s' is not in the current
makefile '%s'. Select the proper target file.
2039: %s
Makefile syntax error: missing colon. The correct syntax is:
: ...
Run XEMAKE -g to create the proper makefile.
2040: The -p and -f options for pin assignment and pin freezing
can not be used together. Choose either one only.
2041: The makefile '%s' is empty or only has comments (ignored).
Run XEMAKE with the -g option to create a correct makefile.
2042: %s
Makefile syntax error: The makefile can not have a target file as
a dependent file also. Run XEMAKE -g to create the proper makefile.
2043: %s
Makefile syntax error: This line must specify at least one
dependent file according to the following syntax:
: ...
Run XEMAKE -g to create the proper makefile.
2044: %s
Makefile syntax error: Only alphanumeric characters are allowed
for this line. The correct syntax is:
: ...
Run XEMAKE -g to create the proper makefile.
2045: Makefile syntax error: no command after a dependency statement.
The correct syntax is:
: ...
Run XEMAKE -g to create the proper makefile.
2046: The FITNET or FITEQN commands are not in the makefile '%s'.
Run XEMAKE -g to create a correct makefile.
2047: PAL component list '%s' does not exist. Verify that this
file is in your directory and has read access before executing PALCONVT.
2048: Bad library option '%d'. The valid values are: '-l 4' to use
the old XEPLD 4.x library or '-l 5' to use the new unified library.
2049: The xnf file '%s.xnf' is missing or can not be read by XEMAKE.
Verify that this file exists and has read access.
2050: The output simulation xnf filename '%s.%s' can not be
the same as the schematic xnf file.
2051: You must append a filename to '@' (i.e., @palfiles.txt). This
filename should contain a list of all PAL files for PALCONVT to process.
2052: The new PLD file has not been specified.
2053: No PAL files were specified. Specify these individual PAL files.
2054: The '%s' netlist was not created because of errors.
Examine '%s.%s' for details.
#
# end of file
#